E-mail: [email protected] http://www.gocct.com
Concurrent Technologies Plc
4 Gilberd Court
Newcomen Way
Colchester, Essex CO4 9WN
United Kingdom
Tel: (+44) 1206 752626
Fax: (+44) 1206 751116
Concurrent Technologies Inc
3840 Packard Road
Suite 130
Ann Arbor, MI 48108
USA
Tel: (734) 971 6309
Fax: (734) 971 6350
Technical Reference Manual
for PP 41x/03x CompactPCI
®
Intel
®
Core Duo
®
Processor
Intelligent Dual PMC Carrier
Manual Order Code 560 0024 Rev 04 January 2007
Vista de página 0
1 2 3 4 5 6 ... 127 128

Resumo do Conteúdo

Página 1

E-mail: [email protected] http://www.gocct.com Concurrent Technologies Plc 4 Gilberd Court Newcomen Way Colchester, Essex CO4

Página 2 - NOTATIONAL CONVENTIONS

x PP 41x/03x TABLE OF FIGURES Figure 1-1 Overview...

Página 3 - GLOSSARY OF TERMS

PC BIOS 10-6 PP 41x/03x The interrupt controller in the 6300ESB ICH can operate in two basic modes, namely PIC (or Non-APIC) mode and APIC mode. PI

Página 4 - REVISION HISTORY

PC BIOS PP 41x/03x 10-7 Table 10-3 lists the typical interrupt structure in APIC mode. A total of 24 interrupts are available. The 6300ESB ICH inte

Página 5 - TABLE OF CONTENTS

PC BIOS 10-8 PP 41x/03x 10.4.3 PCI Device IDs Each PCI bus, and each device on an individual PCI bus, has a unique ID. For the PP 41x/03x, the bus

Página 6

PC BIOS PP 41x/03x 10-9 10.4.4 CompactPCI Bridge Configuration The BIOS provides Setup menus that allow configuration of certain features of the Comp

Página 7

PC BIOS 10-10 PP 41x/03x 10.4.8 Peripheral Mode Window-Size Limitations The CompactPCI bridge forms PCI addresses by concatenating the least signifi

Página 8

PC BIOS PP 41x/03x 10-11 10.5 User Selectable NVRAM Defaults The BIOS provides a facility through which the user can save preferred setup option set

Página 9

PC BIOS 10-12 PP 41x/03x 10.6 The Recovery BIOS In the unlikely event that the board’s BIOS ROM contents becomes corrupted and it is not possible t

Página 10 - TABLE OF FIGURES

PP 41x/03x 11-1 11 SYSTEM MANAGEMENT 11.1 Power Management The Intel Core Duo processor incorporates a mechanism for changing the processor’s operat

Página 11 - TABLE OF TABLES

SYSTEM MANAGEMENT 11-2 PP 41x/03x 11.2 Thermal Management The maximum power dissipation of the Intel Core Duo processor may sometimes be higher than

Página 12

SYSTEM MANAGEMENT PP 41x/03x 11-3 11.2.4 PC BIOS Setup Options The PC BIOS Setup Menu provides control over the thermal management functions, using

Página 13 - 1 INTRODUCTION

PP 41x/03x xi TABLE OF TABLES Table 2-1 Reset Configuration Options...

Página 14 - INTRODUCTION

SYSTEM MANAGEMENT 11-4 PP 41x/03x 11.3 ECC Error Logging The E7520 MCH includes hardware for detecting and correcting single-bit ECC errors and for

Página 15

PP 41x/03x A-1 A SPECIFICATIONS A.1 Functional Specification Processor: • 2.0 GHz or 1.66 GHz Intel Core Duo processor or 2.16 GHz Intel Core 2 Duo

Página 16

SPECIFICATIONS A-2 PP 41x/03x A.2 Environmental Specification (N Series) A.2.1 Temperature Range Operating... 0ºC to +55ºC @ 400LFM

Página 17

SPECIFICATIONS PP 41x/03x A-3 A.3 Dimensions Height... 23.3cm Depth... 16.0cm Width ...

Página 18

SPECIFICATIONS A-4 PP 41x/03x A.4 Electrical Specification A.4.1 Power Supply Requirements Full Speed Actual Speed +5V +5%, -3% +3.3V +5%, -3% +12

Página 19

SPECIFICATIONS PP 41x/03x A-5 A.5 Connectors Figure A-1 Connector Layout Figure A-2 Front Panel Connectors

Página 20

SPECIFICATIONS A-6 PP 41x/03x A.5.1 CompactPCI Interface (J1) Pin-outs The CompactPCI interface connector J1 consists of a 150-pin connector with pi

Página 21

SPECIFICATIONS PP 41x/03x A-7 A.5.2 CompactPCI Interface (J2) Pin-outs The CompactPCI interface connector J2 consists of a 132-pin connector with p

Página 22

SPECIFICATIONS A-8 PP 41x/03x A.5.3 CompactPCI Interface (J3) Pin-outs The CompactPCI interface I/O connector J3 consists of a 114-pin connector wit

Página 23 - 2 HARDWARE INSTALLATION

SPECIFICATIONS PP 41x/03x A-9 A.5.4 CompactPCI Interface (J5) Pin-outs The CompactPCI interface I/O connector J5 consists of a 132-pin connector wi

Página 24 - HARDWARE INSTALLATION

xii PP 41x/03x This page has been left intentionally blank

Página 25

SPECIFICATIONS A-10 PP 41x/03x A.5.5 On-Board Mass Storage Option Connector (P5) Pin-outs Pin No. Signal Name Pin No. Signal Name 1 IDE_RST# 2

Página 26

SPECIFICATIONS PP 41x/03x A-11 A.5.6 PMC Site Connectors (J11 - J14 and J21 - J24) Pin-outs Signal assignments on the PMC connectors are shown in T

Página 27

SPECIFICATIONS A-12 PP 41x/03x Pin No. Signal Name Pin No. Signal Name 1 +12V 2 NC 3 NC 4 NC 5 NC 6 GND 7 GND 8 NC 9 NC 10 NC 11 +3.3V††

Página 28

SPECIFICATIONS PP 41x/03x A-13 Pin No. Signal Name Pin No. Signal Name 1 NC 2 GND 3 GND 4 C/BE(7)# 5 C/BE(6)# 6 C/BE(5)# 7 C/BE(4)# 8 GND 9

Página 29

SPECIFICATIONS A-14 PP 41x/03x Pin No. Signal Name Pin No. Signal Name 1 I/O 1 2 I/O 2 3 I/O 3 4 I/O 4 5 I/O 5 6 I/O 6 7 I/O 7 8 I/O 8 9 I/O

Página 30

SPECIFICATIONS PP 41x/03x A-15 A.5.7 XMC Connector (J25) Pin-out PMC Site 2 is also equipped with an XMC interface connector. The pin-out of this c

Página 31

SPECIFICATIONS A-16 PP 41x/03x A.5.8 Ethernet Connector (P2) Pin-out The front panel Ethernet Interface uses an 8-way RJ45 connector with the follow

Página 32

SPECIFICATIONS PP 41x/03x A-17 A.5.9 Port 80 (S1) Pin-outs Port 80 may be used for debugging purposes and the pin-out for the connector that provid

Página 33

SPECIFICATIONS A-18 PP 41x/03x A.5.10 Shared Front Panel Connector (J6) Pin-outs This connector provides access to the keyboard, mouse, VGA video, CO

Página 34

PP 41x/03x 1-1 1 INTRODUCTION 1.1 General This manual is a guide and reference handbook for engineers and system integrators who wish to use the Con

Página 35

INTRODUCTION 1-2 PP 41x/03x 1.2 The PP 41x/03x - Main Features The PP 41x/03x is a member of the Concurrent Technologies range of single-board comp

Página 36

INTRODUCTION PP 41x/03x 1-3 1.2.4 SDRAM The SDRAM controller within the E7520 MCH supports dual DDR2 400MHz memory channels with ECC data protection.

Página 37

INTRODUCTION 1-4 PP 41x/03x 1.2.11 Ethernet Controllers Three Intel® 82573L Gigabit Ethernet controller are used to provide high performance PCI Exp

Página 38

INTRODUCTION PP 41x/03x 1-5 1.3 Rear Transition Module Peripheral Functions Three Rear Transition Modules (RTMs) may be used with the PP 41x/03x boa

Página 39

INTRODUCTION 1-6 PP 41x/03x 1.3.3 AD PP5/003-0x Peripheral Functions The AD PP5/003-0x RTM provides flexible PMC site rear I/O management by the us

Página 40

INTRODUCTION PP 41x/03x 1-7 1.4 Additional Board Options The PP 41x/03x board may be ordered with one of a few factory fitted configuration options,

Página 41

ii PP 41x/03x NOTES Information furnished by Concurrent Technologies is believed to be accurate and reliable. However, Concurrent Technologies ass

Página 42

INTRODUCTION 1-8 PP 41x/03x 1.5 Extended Temperature Options All variants of the board are qualified for the standard operating and storage tempera

Página 43

INTRODUCTION PP 41x/03x 1-9 1.6 Compliance to RoHS 2002/95/EC This product is offered in a form which complies to the RoHS 2002/95/EC directive. The

Página 44

INTRODUCTION 1-10 PP 41x/03x This page has been left intentionally blank

Página 45 - 3 SOFTWARE INSTALLATION

PP 41x/03x 2-1 2 HARDWARE INSTALLATION 2.1 General This chapter contains general information on unpacking and inspecting the PP 41x/03x after shipme

Página 46 - SOFTWARE INSTALLATION

HARDWARE INSTALLATION 2-2 PP 41x/03x 2.2 Unpacking and Inspection Immediately after the board is delivered to the user’s premises the user should c

Página 47 - SOFTWARE INSTALLATION

HARDWARE INSTALLATION PP 41x/03x 2-3 2.3 Default Jumper and Switch Settings Figure 2-1 Default Jumper and Switch Settings

Página 48

HARDWARE INSTALLATION 2-4 PP 41x/03x 2.4 Front Panel Indicators and Controls When installing or removing the board for the first time, or when chec

Página 49 - 4 MASS STORAGE INTERFACES

HARDWARE INSTALLATION PP 41x/03x 2-5 2.4.8 Switch (SW) A pushbutton switch is recessed behind the front panel, and provides a means of generating a r

Página 50 - MASS STORAGE INTERFACES

HARDWARE INSTALLATION 2-6 PP 41x/03x 2.5 On-board CompactFlash Site A CompactFlash site is provided on the PP 41x/03x board. The site fully suppor

Página 51 - 5 ETHERNET INTERFACES

HARDWARE INSTALLATION PP 41x/03x 2-7 2.6 Battery Installation/Replacement The on-board Real-Time Clock and CMOS memory used by the PC BIOS firmware a

Página 52 - ETHERNET INTERFACES

PP 41x/03x iii GLOSSARY OF TERMS AC’97 ... Audio CODEC 1997 ACPI ... Advanced Configura

Página 53 - 6 OTHER INTERFACES

HARDWARE INSTALLATION 2-8 PP 41x/03x 2.7 Installation of On-Board Mass Storage If an on-board mass storage option has been ordered, it will be nece

Página 54 - OTHER INTERFACES

HARDWARE INSTALLATION PP 41x/03x 2-9 2.7.1 Hard Disk Storage Kit (AD CP1/DR1) The option kit comprises: • A 2.5 inch EIDE disk drive • A ribbon ca

Página 55

HARDWARE INSTALLATION 2-10 PP 41x/03x 2.7.2 CompactFlash Storage Kit (AD 200/001) The option kit comprises: • A CompactFlash carrier module with a

Página 56

HARDWARE INSTALLATION PP 41x/03x 2-11 2.8 Adding or Replacing DRAM Modules The PP 41x/03x accepts standard 200-pin DDR2-400 Registered ECC SODIMM mo

Página 57 - INTERFACE

HARDWARE INSTALLATION 2-12 PP 41x/03x 2.9 Installing or Removing a PMC Module The PP 41x/03x board provides jumper selectable 3.3V or 5V V(I/O) to

Página 58 - 7.2 IPMI Compatibility

HARDWARE INSTALLATION PP 41x/03x 2-13 Figure 2-12 PMC Site 2 Installation Diagram

Página 59 - 7.3 IPMI Overview

HARDWARE INSTALLATION 2-14 PP 41x/03x 2.9.1 PMC Site 2 Bus Speed and Mode Selection The PCI bus connecting to PMC Site 2 can operate at various bus

Página 60 - 7.3.7 Watchdog

HARDWARE INSTALLATION PP 41x/03x 2-15 2.10 CompactPCI Operating Mode Selection This is normally automatic and depends only on what type of slot the

Página 61 - 7.4 Supported Commands

HARDWARE INSTALLATION 2-16 PP 41x/03x 2.11 Reset Sources In addition to the front panel switch described in Section 2.4.8, the board may be reset fr

Página 62 - 7-6 PP 41x/03x

HARDWARE INSTALLATION PP 41x/03x 2-17 2.11.1 CompactPCI Reset The CompactPCI Reset signal is generated by the System Controller and is routed to all

Página 63 - 7.4.3 SEL and SDR Commands

iv PP 41x/03x REVISION HISTORY Revision Summary of Changes Date 01 First Release August 2006 02 Corrected J3 and J5 pin-out tables; changed AD

Página 64 - 7.4.4 Sensor Commands

HARDWARE INSTALLATION 2-18 PP 41x/03x 2.11.2 External Reset When the PP 41x/03x board is used with an AD PP5/001-4xU, AD PP5/002-xx or AD PP5/003-xx

Página 65

HARDWARE INSTALLATION PP 41x/03x 2-19 2.11.3 CompactPCI Push Button Reset The Push Button Reset signal available on the J2 connector (PRST#) will cau

Página 66

HARDWARE INSTALLATION 2-20 PP 41x/03x 2.12 Installation and Power-up Before the board is installed in a CompactPCI chassis, check the following poi

Página 67 - 7.5 FRU Inventory Data

HARDWARE INSTALLATION PP 41x/03x 2-21 2.12.1 Non Hot Swap Procedure - Installing The board is installed and powered up as follows: a) Make sure that

Página 68 - 7.5.2 Board Area

HARDWARE INSTALLATION 2-22 PP 41x/03x 2.12.4 Hot Swap Procedure - Removing To remove the board: a) Open the lower ejector handle and wait for the b

Página 69 - 7.6 Programming Examples

PP 41x/03x 3-1 3 SOFTWARE INSTALLATION In most cases, installing operating system software on the PP 41x/03x board follows the same sequence as inst

Página 70 - 7-14 PP 41x/03x

SOFTWARE INSTALLATION 3-2 PP 41x/03x 3.2 Bootloading from CD-ROM Operating systems that install on the target hardware will generally install from C

Página 71 - PP 41x/03x 7-15

SOFTWARE INSTALLATION PP 41x/03x 3-3 3.3 Installing Microsoft® Windows® Operating Systems Installing these operating systems on the PP 41x/03x is g

Página 72 - 7-16 PP 41x/03x

SOFTWARE INSTALLATION 3-4 PP 41x/03x 3.4 Installing RedHat® Linux® Installing these operating systems on the PP 41x/03x is generally very similar to

Página 73 - PP 41x/03x 7-17

PP 41x/03x 4-1 4 MASS STORAGE INTERFACES The PP 41x/03x board has four interfaces that can be used to attach mass storage devices: • Two Serial A

Página 74

PP 41x/03x v TABLE OF CONTENTS 1 INTRODUCTION... 1-1 1.1 General

Página 75 - 7.6.3 Reading Sensors

MASS STORAGE INTERFACES 4-2 PP 41x/03x This page has been left intentionally blank

Página 76 - 7-20 PP 41x/03x

PP 41x/03x 5-1 5 ETHERNET INTERFACES The PP 41x/03x board is fitted with three independent 1 Gigabit Ethernet interfaces, implemented with three Int

Página 77 - 7.7 In System Programming

ETHERNET INTERFACES 5-2 PP 41x/03x This page has been left intentionally blank

Página 78 - 7-22 PP 41x/03x

PP 41x/03x 6-1 6 OTHER INTERFACES Many additional standard interfaces are provided on the PP 41x/03x board. These interfaces consist primarily of t

Página 79 - 8 FLASH EPROM AND DRAM

OTHER INTERFACES 6-2 PP 41x/03x 6.1.1 PC BIOS Serial Console With some operating systems, or in some applications, it is preferable to use a serial

Página 80 - FLASH EPROM AND DRAM

OTHER INTERFACES PP 41x/03x 6-3 6.1.2 PC BIOS Serial Console Port When the PC BIOS is configured to use a serial port for its console, either COM1 o

Página 81

OTHER INTERFACES 6-4 PP 41x/03x 6.2 Keyboard and Mouse Ports The PP 41x/03x provides PS/2™ type keyboard and mouse interfaces via the front panel C

Página 82

PP 41x/03x 7-1 7 INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7.1 Introduction The Intelligent Platform Management Interface (IPMI) is an industry-sta

Página 83 - CONSOLE USER MODE

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-2 PP 41x/03x 7.2 IPMI Compatibility This board implements a version of IPMI compatible with revision 1.5

Página 84

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-3 7.3 IPMI Overview The PP 41x/03x board includes hardware and firmware that implements an IPM

Página 85

vi PP 41x/03x 2.10 CompactPCI Operating Mode Selection...2-15 2.11 Re

Página 86

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-4 PP 41x/03x 7.3.4 Sensors The PP 41x/03x board is capable of monitoring the temperature of the board an

Página 87 - 9.5 CPCI Status Register

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-5 7.4 Supported Commands The PP 41x/03x board supports a subset of the command messages as def

Página 88

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-6 PP 41x/03x NetFn CMD Get Device ID 06h 01h Broadcast Get Device ID 06h 01h Cold Reset 06h 02h Warm

Página 89 - D7 D6 D5 D4 D3 D2 D1 D0

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-7 7.4.1 Get Self Test Results Command On this board, no self test results are available via t

Página 90 - 9-10 PP 41x/03x

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-8 PP 41x/03x 7.4.4 Sensor Commands The list of sensors fitted to this board, together with the sensor nu

Página 91

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-9 7.4.4.1 Board and CPU Temperature Sensors An Analog Devices ADT7461 device measures the loc

Página 92 - 9.10 IPMI SMIC Interface

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-10 PP 41x/03x 7.4.4.10 Ejector Handle This sensor reading indicates the status of the ejector handle swi

Página 93 - 9.11 P.O.S.T. LED / Speaker

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-11 7.5 FRU Inventory Data The FRU Inventory Area shares the non-volatile memory with the repo

Página 94 - 9.12 PORT 80

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-12 PP 41x/03x 7.5.2 Board Area The Board Area, in the FRU Inventory, contains information about the PP 4

Página 95 - 10 PC BIOS

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-13 7.6 Programming Examples 7.6.1 Using the SMIC Interface The PP 41x/03x board utilizes the

Página 96

PP 41x/03x vii 7.3.6 Field Replaceable Unit Inventory Data ...7-4

Página 97

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-14 PP 41x/03x /****************************************************************************** * * vBm

Página 98

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-15 */ void vBmcSmicSmsMessageRead ( unsigned char *pbMessage, /* received response

Página 99

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-16 PP 41x/03x 7.6.2 Using the Watchdog Timer The IPMI provides a standardized watchdog facility which i

Página 100 - PC BIOS

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-17 /****************************************************************************** * * wSetW

Página 101

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-18 PP 41x/03x unsigned char bLength; unsigned short int wStatus = E_OK; abRequest [0] = NFC

Página 102

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-19 7.6.3 Reading Sensors The IPMI specification supports many commands to manage and interroga

Página 103

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-20 PP 41x/03x unsigned char abRequest [10]; unsigned char abResponse [10]; unsigned short i

Página 104

INTELLIGENT PLATFORM MANAGEMENT INTERFACE PP 41x/03x 7-21 7.7 In System Programming The PP 41x/03x allows the IPMI microcontroller firmware to be up

Página 105

INTELLIGENT PLATFORM MANAGEMENT INTERFACE 7-22 PP 41x/03x This page has been left intentionally blank

Página 106

PP 41x/03x 8-1 8 FLASH EPROM AND DRAM 8.1 Flash EPROM The PP 41x/03x is fitted with one Flash EPROM part, namely an Intel 82802AC8 or equivalent Fi

Página 107 - 11 SYSTEM MANAGEMENT

viii PP 41x/03x 9.10.1 SMIC Data Register ...

Página 108 - SYSTEM MANAGEMENT

FLASH EPROM AND DRAM 8-2 PP 41x/03x This page has been left intentionally blank

Página 109 - SYSTEM MANAGEMENT

PP 41x/03x 9-1 9 ADDITIONAL LOCAL I/O FUNCTIONS The PP 41x/03x supports a variety of I/O functions whose addresses are summarized in Table 9-1. NOT

Página 110

ADDITIONAL LOCAL IO FUNCTIONS 9-2 PP 41x/03x Most of the addresses are standard PC-AT compatible values, but at addresses 0210h - 021Fh and 0CA9h –

Página 111 - A SPECIFICATIONS

ADDITIONAL LOCAL IO FUNCTIONS PP 41x/03x 9-3 9.1 Status & Control Register 0 This register is at I/O address 210h. 7 6 5 4 3 2 1 0 REV2 RE

Página 112 - SPECIFICATIONS

ADDITIONAL LOCAL IO FUNCTIONS 9-4 PP 41x/03x 9.2 Status & Control Register 1 This register is at I/O address 211h. 7 6 5 4 3 2 1 0 FP NMI I

Página 113 - SPECIFICATIONS

ADDITIONAL LOCAL IO FUNCTIONS PP 41x/03x 9-5 9.3 Status & Control Register 2 This register is at I/O address 212h. 7 6 5 4 3 2 1 0 XMC MBI

Página 114

ADDITIONAL LOCAL IO FUNCTIONS 9-6 PP 41x/03x 9.4 General Purpose I/O Register This register is at I/O address 213h. 7 6 5 4 3 2 1 0 EXT RESET

Página 115

ADDITIONAL LOCAL IO FUNCTIONS PP 41x/03x 9-7 9.5 CPCI Status Register This register is at I/O address 214h. 7 6 5 4 3 2 1 0 RFU FAL# DEG# CPCI V(I

Página 116

ADDITIONAL LOCAL IO FUNCTIONS 9-8 PP 41x/03x 9.6 Interrupt Control Register This register is at I/O address 215h. It provides control over interrup

Página 117

ADDITIONAL LOCAL IO FUNCTIONS PP 41x/03x 9-9 9.7 Temperature Sensor Data Register This register provides a convenient means of reading the analog te

Página 118

PP 41x/03x ix A.5.2 CompactPCI Interface (J2) Pin-outs ... A-7

Página 119

ADDITIONAL LOCAL IO FUNCTIONS 9-10 PP 41x/03x 9.8 ACPI PM1 Control Register This 16-bit register is located at I/O addresses 21Eh and 21Fh. It prov

Página 120

ADDITIONAL LOCAL IO FUNCTIONS PP 41x/03x 9-11 9.9 Interrupt Configuration Register This register is at I/O address 21Dh. 7 6 5 4 3 2 1 0 IPMI IN

Página 121

ADDITIONAL LOCAL IO FUNCTIONS 9-12 PP 41x/03x 9.10 IPMI SMIC Interface The IPMI sub-system is accessed by the local CPU using the SMIC interface (s

Página 122

ADDITIONAL LOCAL IO FUNCTIONS PP 41x/03x 9-13 9.11 P.O.S.T. LED / Speaker The P.O.S.T. LED is controlled via the speaker port. The P.O.S.T. LED rep

Página 123

ADDITIONAL LOCAL IO FUNCTIONS 9-14 PP 41x/03x 9.12 PORT 80 A header (S1 – see Figure A-1) has been provided for monitoring data written to I/O Port

Página 124

PP 41x/03x 10-1 10 PC BIOS The PP 41x/03x board is fitted with PC BIOS firmware that performs many of the functions of a standard desktop PC. It al

Página 125

PC BIOS 10-2 PP 41x/03x Operator communication with the PC BIOS is usually through a serial terminal connected to the COM1 or COM2 serial ports. Thi

Página 126

PC BIOS PP 41x/03x 10-3 10.2 The PC BIOS Startup Sequence When the board starts up without operator intervention, it will run a basic Power-On Self-

Página 127

PC BIOS 10-4 PP 41x/03x 10.3 Boot Device Selection The order in which the PC BIOS searches for a bootable medium is pre-configured but may be alter

Página 128

PC BIOS PP 41x/03x 10-5 10.4 PCI Bus Resource Management The bus structure of the PP 41x/03x is complex. There are three on-board PCI busses, namel